{"title":"Monitoring Relays","description":"\u003cp dir=\"auto\"\u003eMonitoring or control relays from Pelek.uk are vital for monitoring electrical parameters in industrial applications. Designed by a leading Turkish manufacturer TENSE Elektrinik, they provide accurate oversight of voltage, current and other key factors essential for the safe and efficient operation of equipment. Available in a variety of models to suit specific requirements, our monitoring relays deliver precision, reliability and safety. Pelek.uk offers premium quality together with fast delivery and expert technical support:\u003c\/p\u003e","products":[{"product_id":"digital-overcurrent-relay-with-3-3-digit-led-display-trm-100","title":"3 phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay 40A – 100A","description":"\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=LoQmCd_90\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 class=\"n6owBd awi2gc\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"\u003eThis current monitoring relay is designed by Tense Electronics to protect electrical loads (such as three-phase motors, heaters, and transformers) from high current damage. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=LoQmCd_90\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications \u0026amp; Features\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eTripping Current Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Adjustable overload protection between \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e40A and 100A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Asymmetry:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fixed at \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e50%\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e error threshold to guard against phase imbalances.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDisplay Interface:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Equipped with a \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e3×3 digit LED display\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e for real-time monitoring of three-phase currents.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperation Reset Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Features three user-adjustable reset methods: \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAutomatic, Semi-Automatic, and Manual\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eTime Delays:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fully \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eadjustable error delay times\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (0.1 to 20 seconds) to prevent nuisance tripping during temporary inrush currents.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAc\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Standard \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e installation.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAg\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIncluded Components:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The retail box comes complete with required external \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ecurrent transformers\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=LoQmCd_ag\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperational Principle\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAA\" data-processed=\"true\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAI\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eStartup:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e When energized, the relay activates, illuminating the \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOUT\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e indicator and closing the circuit via its output contact.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAU\" data-processed=\"true\" data-sae=\"\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOverload Event:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e If the drawn current on any phase surpasses the defined threshold value (A\u0026gt;), the \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eERR\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e warning light turns on, and a localized countdown timer begins.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAg\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eTripping Action:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e If the overcurrent state outlasts the preconfigured delay window, the relay safely cuts the contact output, turning off the OUT light to isolate the downstream load.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=H0ibqc_4p\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Application\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQggEAA\" data-complete=\"true\" data-processed=\"true\"\u003eUnlike traditional mechanical thermal relays, the microprocessor-based TRM-100 monitoring relay provides much more precise real-time current tracking and protection against phase imbalances or overcurrent faults, effectively extending the service life of industrial electric motors.\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173237809482,"sku":"TRM-100","price":43.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/TRM-100.png?v=1792946740"},{"product_id":"digital-overcurrent-relay-with-3-3-digit-led-display-trm-200","title":"3 phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay 90A – 200A","description":"\u003ch2 class=\"n6owBd awi2gc\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"\u003eThis current monitoring relay is designed by Tense Electronics to protect electrical loads (such as three-phase motors, heaters, and transformers) from high current damage. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c\/h2\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_2n\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_2n\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Control Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e90A to 200A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (adjustable overload value).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDisplay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 3×3 digit LED display for real-time monitoring of three-phase currents.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAsymmetry Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fixed at \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e50% current asymmetry\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e error.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDelay Time:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Programmable error delay time ranging from \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e1 second to 200 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting Type:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Designed for standard \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e installation.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAc\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOutput Contact:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 5A (1 x CO changeover contact).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_3y\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperational Characteristics\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperating Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The device features three adjustable reset modes to return to normal operation after a fault:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAM\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eManual:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Requires physical human intervention to reset.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSemi-Automatic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Resets automatically under specific programmatic constraints.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAutomatic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Disconnects and reconnects the load automatically based on user-defined cooling\/return times.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAs\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIncluded Components:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The package is sold as a ready-to-use solution and \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eincludes the necessary external current transformers\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=H0ibqc_4p\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Application\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQggEAA\" data-complete=\"true\" data-processed=\"true\"\u003eUnlike traditional mechanical thermal relays, the microprocessor-based TRM-200 monitoring relay provides much more precise real-time current tracking and protection against phase imbalances or overcurrent faults, effectively extending the service life of industrial electric motors.\u003c\/div\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173239578954,"sku":"TRM-200","price":47.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/TRM-200.png?v=1792947348"},{"product_id":"direct-digital-overcurrent-relay-with-3-3-digit-led-display-trm-25","title":"3 phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay 0,1A – 25A","description":"\u003ch2 class=\"n6owBd awi2gc\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"\u003eThis current monitoring relay is designed by Tense Electronics to protect electrical loads (such as three-phase motors, heaters, and transformers) from high current damage. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=OKoQdc_19\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=OKoQdc_19\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=OKoQdc_19\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications of TRM-25\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Adjustable from \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e0.1 A to 25 A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperating Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 150–260 V AC (50\/60 Hz).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAsymmetry Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Features a \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e50% fixed current asymmetry error\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e to prevent damage during unbalanced phase loads or phase loss.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eInternal Current Transformers:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Built directly into the unit, eliminating the need for external current transformers.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Designed for standard \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e installation.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAc\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOutput Contacts:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 5 A \/ 250 V AC active load.\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=OKoQdc_2j\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eWorking Principle \u0026amp; Operation of the monitoring relay\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgVEAA\" data-processed=\"true\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgVEAI\" data-sae=\"\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eStartup Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Upon being energized or reset, the device bypasses current control for 5 seconds to accommodate initial motor starting inrush currents.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgVEAc\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAdjustments:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Users can set the high current limit using the \u003ccode dir=\"ltr\" class=\"KDcb0c\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003eA\u0026gt;\u003c!--TgQPHd|||[]--\u003e\u003c\/code\u003e knob and configure the error delay time (0.1–20 seconds) via the \u003ccode dir=\"ltr\" class=\"KDcb0c\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003et\u003c!--TgQPHd|||[]--\u003e\u003c\/code\u003e knob.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgVEAw\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eTripping Mechanism:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e If the current surpasses the configured threshold, the unit tracks the set delay time. Once elapsed, the relay de-energizes, shifting contact output from terminal 3 to terminal 1 and shutting off the \"OUT\" LED.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgVEBE\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperation Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Features adjustable manual, semi-automatic, or fully automatic reset configurations.\u003cbr\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173243085130,"sku":"TRM-25","price":32.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/TRM-25.png?v=1792945711"},{"product_id":"digital-overcurrent-relay-with-3-3-digit-led-display-trm-300","title":"3 phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay 190A – 300A","description":"\u003ch2 class=\"n6owBd awi2gc\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"\u003eThis current monitoring relay is designed by Tense Electronics to protect electrical loads (such as three-phase motors, heaters, and transformers) from high current damage. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c\/h2\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_2n\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_2n\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Control Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e190A to 300A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (adjustable overload value).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDisplay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 3×3 digit LED display for real-time monitoring of three-phase currents.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAsymmetry Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fixed at \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e50% current asymmetry\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e error.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDelay Time:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Programmable error delay time ranging from \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e1 second to 200 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting Type:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Designed for standard \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e installation.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAc\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOutput Contact:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 5A (1 x CO changeover contact).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_3y\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperational Characteristics\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperating Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The device features three adjustable reset modes to return to normal operation after a fault:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAM\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eManual:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Requires physical human intervention to reset.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSemi-Automatic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Resets automatically under specific programmatic constraints.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAutomatic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Disconnects and reconnects the load automatically based on user-defined cooling\/return times.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAs\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIncluded Components:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The package is sold as a ready-to-use solution and \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eincludes the necessary external current transformers\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=H0ibqc_4p\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Application\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQggEAA\" data-complete=\"true\" data-processed=\"true\"\u003eUnlike traditional mechanical thermal relays, the microprocessor-based TRM-300 monitoring relay provides much more precise real-time current tracking and protection against phase imbalances or overcurrent faults, effectively extending the service life of industrial electric motors.\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173244264778,"sku":"TRM-300","price":79.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/TRM-300.png?v=1792947677"},{"product_id":"digital-overcurrent-relay-with-overvoltage-protection-trm-30m","title":"Single phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay with under\/overvoltage protection 0,5A – 30A","description":"\u003ch2\u003eTENSE TRM-30M is a single-phase, DIN-rail mounted voltage-protected digital overload relay manufactured by Tense Electronic. It is engineered to safeguard sensitive electrical equipment from faults caused by mains voltage fluctuations (overvoltage\/undervoltage) and current overloads. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c\/h2\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eCore Protective Functions\u003c\/h3\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOverload Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Supports an adjustable current range from \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e0.5A to 30A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOvervoltage Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fixed activation threshold set at \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u0026gt; 250V\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eUndervoltage Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fixed activation threshold set at \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u0026lt; 150V\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=QYSBTe_3g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eTechnical Specifications\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgbEAA\" data-complete=\"true\" data-processed=\"true\"\u003eA breakdown of the electrical and physical specifications :\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"Fv6NCb\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Q-q4QeggIAggBCBwQAA\" data-hveid=\"CAIIAQgcEAA\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\n\u003ctable class=\"NRefec\" data-animation-nesting=\"\" data-sae=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQAQ\" data-complete=\"true\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eParameter\u003c!--TgQPHd|||[]--\u003e\n\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSpecification\u003c!--TgQPHd|||[]--\u003e\n\u003c\/th\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQAg\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperating Voltage (Un)\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e230V AC (50\/60 Hz)\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQAw\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePower Consumption\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u0026lt; 6VA\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQBA\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eError Delay Time (t)\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAdjustable from 1 second to 20 seconds\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQBQ\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eVoltage Hysteresis \/ Reset Delay\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e5V (Fixed) \/ 2 seconds\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQBg\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOutput Contact\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e5A \/ 250V AC (Resistive load)\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQBw\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDisplay Type\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eClear 2-line, 3-digit LED screen\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQCA\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting \u0026amp; Wiring\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail mounted; clamp connection up to 2.5 mm²\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"l2uqvb\" data-visible=\"1\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjD-smsxNWXAxVjcfEDHVTMBK8Qw4oVeggIAggBCBwQCQ\" data-complete=\"true\"\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIncluded Accessories\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003ctd class=\"Vk1lqb\" colspan=\"undefined\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eExternal current measuring transformer\u003c!--TgQPHd|||[]--\u003e\n\u003c\/td\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!--TgQPHd|||[[1,0,0,2,null,\u0026quot;\u0026quot;]]--\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=QYSBTe_4s\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=QYSBTe_4s\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Features\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eReal-time Monitoring:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The upper line of the LED display indicates line voltage and overcurrent, while the lower line displays the current load and active delay timers.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eVisual Diagnostics:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Features a dedicated \"OUT\" status LED to signify if the output relay is actively engaged or tripped.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIndustrial Build:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Built to function reliably within a wide operating temperature range of -20°C to +55°C.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQghEAA\" data-complete=\"true\" data-processed=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173253505354,"sku":"TRM-30M","price":37.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/1bea46524163a74db8b8805646b09c3a_7a0f2036-8fd1-43e8-bebe-2c6e40d22989.png?v=1761817855"},{"product_id":"digital-overcurrent-relay-with-led-display-3-3-digits-trm-400","title":"3 phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay 290A – 400A","description":"\u003ch2 class=\"n6owBd awi2gc\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"\u003eThis current monitoring relay is designed by Tense Electronics to protect electrical loads (such as three-phase motors, heaters, and transformers) from high current damage. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c\/h2\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_2n\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_2n\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Control Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e290A to 400A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (adjustable overload value).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAM\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDisplay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 3×3 digit LED display for real-time monitoring of three-phase currents.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAsymmetry Protection:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Fixed at \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e50% current asymmetry\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e error.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDelay Time:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Programmable error delay time ranging from \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e1 second to 200 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting Type:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Designed for standard \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e installation.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAc\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOutput Contact:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 5A (1 x CO changeover contact).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=atM5Ed_3y\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperational Characteristics\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOperating Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The device features three adjustable reset modes to return to normal operation after a fault:\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAM\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAQ\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eManual:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Requires physical human intervention to reset.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAU\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSemi-Automatic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Resets automatically under specific programmatic constraints.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAutomatic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Disconnects and reconnects the load automatically based on user-defined cooling\/return times.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAs\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIncluded Components:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The package is sold as a ready-to-use solution and \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eincludes the necessary external current transformers\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=H0ibqc_4p\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Application\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQggEAA\" data-complete=\"true\" data-processed=\"true\"\u003eUnlike traditional mechanical thermal relays, the microprocessor-based TRM-400 monitoring relay provides much more precise real-time current tracking and protection against phase imbalances or overcurrent faults, effectively extending the service life of industrial electric motors.\u003c\/div\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173255045450,"sku":"TRM-400","price":92.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/TRM-400.png?v=1792948011"},{"product_id":"digital-overcurrent-relay-with-led-display-3-3-digits-trm-50","title":"3 phase digital overload overcurrent relay  \/ current monitoring relay \/ priority relay 15A – 50A","description":"\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=H0ibqc_2g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 class=\"n6owBd awi2gc\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"\u003eThis current monitoring relay is designed by Tense Electronics to protect electrical loads (such as three-phase motors, heaters, and transformers) from high current damage. It also can monitor electrical current on a main or priority circuit. If the current exceeds a set threshold, the relay cuts off non-priority circuits to prevent breaker trips, then automatically restores them when current drops.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=H0ibqc_2g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=H0ibqc_2g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=H0ibqc_2g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications \u0026amp; Features\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEAA\" data-complete=\"true\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEAI\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Range:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e It features an adjustable overload tripping current value ranging from \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e15A to 50A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEAc\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDisplay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Equipped with a \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e3×3 digit LED display\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e that shows real-time current measurements for all three phases, allowing operators to monitor system loads directly.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEAw\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAsymmetry Error:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e It features a \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e50% fixed current asymmetry error\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e protection mechanism.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEBE\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDelay Time:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Features an \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eadjustable error delay time\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e. This allows the system to tolerate temporary high current spikes, such as during a motor's initial startup (demeraj), without triggering a nuisance trip.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEBY\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eReset Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Offers three programmable operation reset modes to return to an operational state: \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAutomatic, Semi-Automatic, or Manual\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEBs\" data-complete=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eMounting \u0026amp; Packaging:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Designed for standard \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDIN rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e mounting and comes included with the necessary external current transformers in the box.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=H0ibqc_4p\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePrimary Application\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQggEAA\" data-complete=\"true\" data-processed=\"true\"\u003eUnlike traditional mechanical thermal relays, the microprocessor-based TRM-50 provides much more precise real-time current tracking and protection against phase imbalances or overcurrent faults, effectively extending the service life of industrial electric motors.\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173255635274,"sku":"TRM-50","price":39.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/TRM-50.png?v=1792946300"},{"product_id":"programmable-digital-potentiometer-4-20ma-100_240vac-24vdcac-two-digital-inputs-4-digit-led-ptm-02-tense","title":"Programmable Digital Potentiometer, 4-20mA, 100..240VAC and 24VDC\/AC, Two Digital Inputs, 4-Digit LED, PTM-02, TENSE","description":"\u003ch1\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e4-20mA\u003c\/span\u003e digital potentiometer with wide voltage supply range and two digital inputs (+\/-), TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003eThe Tense PTM-02 is a microprocessor-based digital potentiometer designed to produce an analog output of \u003cmeta charset=\"utf-8\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e4-20mA\u003c\/span\u003e for use in industrial automation and control systems. It is manufactured by Tense Electronics, a Turkish company. \u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e Provides a precise \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e4-20mA\u003c\/span\u003e analog current output (\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/pelek.uk\/products\/digital-potentiometer-0-10v-voltage-source?_pos=1\u0026amp;_sid=877a3014d\u0026amp;_ss=r\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eor 0-10V DC in PTM-01\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eUser Control:\u003c\/strong\u003e Output values can be adjusted via up\/down push buttons on the front panel or through external up\/down digital inputs (dry contact only).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e Features a bright and clear 4-digit, 7-segment LED display.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003eProgrammable Limits: The user can set adjustable upper and lower limits for the analog output and the set value.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cstrong\u003eWide range voltage supply\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e Settings are stored in EEPROM memory to retain them in case of power failure.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e Compact, space-saving design intended for DIN rail or permanent panel installation.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Ideal for applications such as motor speed control (VFDs), dimming systems, and PLC analog input management. \u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cstrong\u003ePassword protection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTECHNICAL SPECIFICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 35x77mm\u003c\/li\u003e\n\u003cli\u003ePanel Cut-out: 29x71mm\u003c\/li\u003e\n\u003cli\u003eDisplay: 4 Digits 7 Segment\u003c\/li\u003e\n\u003cli\u003eAnalog Output: 4-20mA \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e4-20mA max. Voltage: \u0026lt;10V\u003c\/li\u003e\n\u003cli\u003eResolution: 4μA (4-20mA)\u003c\/li\u003e\n\u003cli\u003eAccuracy:±%1;(Over full scale)\u003c\/li\u003e\n\u003cli\u003eUser Control: Via Up\/Down Front Panel Keys or Up\/Down Digital Inputs\u003c\/li\u003e\n\u003cli\u003eDigital Inputs: Dry contact input only\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 100..240VAC, 50-60Hz or 24VDC\/AC.\u003c\/li\u003e\n\u003cli\u003ePower Consumption: \u0026lt; 6VA\u003c\/li\u003e\n\u003cli\u003eHumidity: 80% up to 30oC, then linearly decreases to 50% at 50oC (non-condensing)\u003c\/li\u003e\n\u003cli\u003eAltitude: \u0026lt; 2000 m\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20\u003c\/li\u003e\n\u003cli\u003eOperation Temp.: 0 .. 50 oC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -10oC .. 60oC (no icing)\u003c\/li\u003e\n\u003cli\u003eWeight: \u0026lt; 0.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173727297866,"sku":"PTM-02","price":41.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Programmable_Digital_Potentiometer_4-20mA_100..240VAC_and_24VDC_AC_Two_Digital_Inputs_4-Digit_LED_PTM-02_TENSE.jpg?v=1768567559"},{"product_id":"programmable-digital-potentiometer-0-10v-100-240vac_24vdcac-ptm-01-tense","title":"Programmable Digital Potentiometer, 0-10V, 100..240VAC and 24VDC\/AC, Two Digital Inputs, 4-Digit LED, PTM-01, TENSE","description":"\u003ch1\u003e0-10V digital potentiometer with wide voltage supply range and two digital inputs (+\/-), TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003eThe Tense PTM-01 is a microprocessor-based digital potentiometer designed to produce an analog output of 0-10V for use in industrial automation and control systems. It is manufactured by Tense Electronics, a Turkish company. \u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e Provides a precise 0-10V DC analog voltage output (\u003cem\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/pelek.uk\/products\/digital-potentiometer-current-source-4-20ma?_pos=2\u0026amp;_sid=3fecebf45\u0026amp;_ss=r\" target=\"_blank\"\u003eor 4-20mA in PTM-02\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eUser Control:\u003c\/strong\u003e Output values can be adjusted via up\/down push buttons on the front panel or through external up\/down digital inputs (dry contact only).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e Features a bright and clear 4-digit, 7-segment LED display.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003eProgrammable Limits: The user can set adjustable upper and lower limits for the analog output and the set value.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cstrong\u003eWide range voltage supply\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e Settings are stored in EEPROM memory to retain them in case of power failure.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e Compact, space-saving design intended for DIN rail or permanent panel installation.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Ideal for applications such as motor speed control (VFDs), dimming systems, and PLC analog input management. \u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cstrong\u003ePassword protection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTECHNICAL SPECIFICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 35x77mm\u003c\/li\u003e\n\u003cli\u003ePanel Cut-out: 29x71mm\u003c\/li\u003e\n\u003cli\u003eDisplay: 4 Digits 7 Segment\u003c\/li\u003e\n\u003cli\u003eAnalog Output: 0-10V\u003c\/li\u003e\n\u003cli\u003e0-10V Load Imped.: \u0026gt;5K\u003c\/li\u003e\n\u003cli\u003eResolution: 2mV (0-10V)\u003c\/li\u003e\n\u003cli\u003eAccuracy:±%1;(Over full scale)\u003c\/li\u003e\n\u003cli\u003eUser Control: Via Up\/Down Front Panel Keys or Up\/Down Digital Inputs\u003c\/li\u003e\n\u003cli\u003eDigital Inputs: Dry contact input only\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 100..240VAC, 50-60Hz or 24VDC\/AC.\u003c\/li\u003e\n\u003cli\u003ePower Consumption: \u0026lt; 6VA\u003c\/li\u003e\n\u003cli\u003eHumidity: 80% up to 30oC, then linearly decreases to 50% at 50oC (non-condensing)\u003c\/li\u003e\n\u003cli\u003eAltitude: \u0026lt; 2000 m\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP20\u003c\/li\u003e\n\u003cli\u003eOperation Temp.: 0 .. 50 oC\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -10oC .. 60oC (no icing)\u003c\/li\u003e\n\u003cli\u003eWeight: \u0026lt; 0.5 kg\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53173730378058,"sku":"PTM-01","price":39.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Programmable_Digital_Potentiometer_0-10V_100..240VAC_and_24VDC_AC_Two_Digital_Inputs_4-Digit_LED_PTM-01_TENSE.jpg?v=1768567524"},{"product_id":"3-phase-under-over-voltage-monitoring-relay-phase-fail-sequence-control-din-rail-mount-380v-ac-spdt-gkt-03f-tense","title":"3 Phase Under \/ Over Voltage Monitoring Relay With Phase Fail \/ Sequence Control, Without Neutral Connection,DIN Rail Mount, 380V AC, SPDT, GKT-03F, TENSE","description":"\u003ch1 class=\"p1\"\u003e3 Phase under \/ over voltage monitoring relay with phase fail \/ sequence control, DIN rail mount, supply voltage -  380V AC,  NO+NC, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe GKT-03F by Tense Electronics is an analogue adjustable voltage control relay designed to protect three-phase systems without a neutral connection from voltage fluctuations and phase sequence errors. \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003eOver-Voltage Protection: Monitors and trips if voltage exceeds the set limit (adjustable between 400V - 510V AC).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003eUnder-Voltage Protection: Monitors and trips if voltage drops below the set limit (adjustable between 260V - 370V AC).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003ePhase Sequence Control: Ensures the correct order of phases; the relay will not activate if the sequence is reversed.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003ePhase Failure Protection: Detects the absence of a phase and deactivates the relay to prevent equipment damage.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eTime delays adjustable for Fault detection and Fault reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: 380V AC 50\/60 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174056649034,"sku":"GKT-03F","price":28.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/3_Phase_Under_Over_Voltage_Monitoring_Relay_With_Phase_Fail_Sequence_Control_Without_Neutral_Connection_DIN_Rail_Mount_380V_AC_SPDT_GKT-03F_TENSE.png?v=1768908346"},{"product_id":"3-phase-under-over-voltage-monitoring-relay-phase-failure-sequence-control-220-240v-ac-spdt-gkm-tense","title":"3 Phase Under \/ Over Voltage Monitoring Relay With Phase Fail \/ Sequence Control, 220-240V AC, DIN Rail Mount, SPDT, GKM, TENSE","description":"\u003ch1 class=\"p1\"\u003e3 Phase under \/ over voltage monitoring relay with phase control, voltage supply 220V-240V AC, DIN Rail Mount, NO+NC, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003eThe GKT-03F by Tense Electronics is an analogue adjustable voltage control relay designed to protect three-phase systems without a neutral connection from voltage fluctuations and phase sequence errors. \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eKey Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eOver-Voltage Protection:\u003c\/strong\u003e Monitors and trips if voltage exceeds the set limit (adjustable between 230V - 300V AC).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eUnder-Voltage Protection:\u003c\/strong\u003e Monitors and trips if voltage drops below the set limit (adjustable between 140V - 210V AC).\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003ePhase Sequence Control (GKM-03F)\u003c\/strong\u003e: Ensures the correct order of phases; the relay will not activate if the sequence is reversed .\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003ePhase Failure Protection:\u003c\/strong\u003e Detects the absence of a phase and deactivates the relay to prevent equipment damage.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eTime delays adjustable for Fault detection and Fault reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: 220V AC 50\/60 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":53174057107786,"sku":"GKM-02F","price":28.0,"currency_code":"GBP","in_stock":true},{"title":"No","offer_id":53174057140554,"sku":"GKM-02","price":24.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/3_Phase_Under_Over_Voltage_Monitoring_Relay_With_Phase_Fail_Sequence_Control_220-240V_AC_DIN_Rail_Mount_SPDT_GKM-02_TENSE.webp?v=1768908251"},{"product_id":"protective-three-phase-monitoring-relay-for-controlling-the-phases-trip-asym-trace","title":"Compact And Simple Phase Failure, Asymmetry Monitoring Relay, 3 Phase, DIN rail mount, SPDT, FKV-11, TENSE","description":"\u003ch1 class=\"p1\"\u003eSimple phase failure and  asymmetry monitoring relay for 3 phase, DIN rail mount, SPDT, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe FKV-11 is an phase failure monitoring relay with asymmetry monitoring relay manufactured by Tense Electronics. It is designed to protect three-phase motors and loads from electrical damage caused by AC voltage irregularities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase loss detection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eFixed phase asymmetry trip level: 30%\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eAutomatic reset on fault removal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e2xLED for relay status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eIt is primarily used to safeguard: \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Prevents overheating and burnout from phase imbalances or loss.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eCompressors:\u003c\/strong\u003e Protects against reverse rotation caused by incorrect phase sequence.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Acts as a general-purpose protection relay for three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: \u003cmeta charset=\"utf-8\"\u003e220V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;4VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN rail.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174058615114,"sku":"FKV-11","price":15.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/09a2549e4774d8a6dda02acdfbfcacc0_c1b3d87f-a0e3-4580-9837-080132d24316.png?v=1761822730"},{"product_id":"phase-failure-monitoring-relay-3-phase-sequence-relay-din-rail-mount-spdt-fkv-03n-tense","title":"Simple And Compact Phase Failure Monitoring Relay, 3 Phase Sequence Relay, DIN rail mount, SPDT, FKV-03N, TENSE","description":"\u003ch1 class=\"p1\"\u003eSimple, slim phase sequence failure monitoring relay for 3 phase, DIN rail mount, SPDT, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e  \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe FKV-03N is an phase failure and phase sequence monitoring relay manufactured by Tense Electronics. It is designed to protect three-phase motors and loads from electrical damage caused by AC voltage irregularities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003ePhase Sequence \/ Reverse detection;\u003c\/li\u003e\n\u003cli\u003ePhase loss detection\u003cmeta charset=\"utf-8\"\u003e \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eAutomatic reset on fault removal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e2xLED for relay status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eIt is primarily used to safeguard: \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Prevents overheating and burnout from phase imbalances or loss.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eCompressors:\u003c\/strong\u003e Protects against reverse rotation caused by incorrect phase sequence.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Acts as a general-purpose protection relay for three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: 380V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN rail.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174058844490,"sku":"FKV-03N","price":14.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Simple_And_Compact_Phase_Failure_Monitoring_Relay_3_Phase_Sequence_Relay_DIN_rail_mount_SPDT_FKV-03N_TENSE.png?v=1772196636"},{"product_id":"phase-failure-asymmetry-and-under-over-voltage-monitoring-relay-3-phase-fail-relay-din-rail-mount-spdt-fkt-06f-tense","title":"Phase Failure, Asymmetry and Under \/ Over Voltage Monitoring Relay, 3 Phase Fail Relay, DIN rail mount, no neutral, SPDT, FKT-06F, TENSE","description":"\u003ch1 class=\"p1\"\u003ePhase failure, asymmetry detection and under \/ over voltage protection relay with NO+NC output, without neutral, DIN rail mount, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe FKT-06F is an asymmetry-adjustable phase failure and sequence monitoring relay with under\/over voltage protection manufactured by Tense Electronics. It is designed to protect three-phase motors and loads from electrical damage caused by AC voltage irregularities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003ePhase Sequence \/ Reverse detection;\u003c\/li\u003e\n\u003cli\u003ePhase loss detection; \u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eAdjustable phase asymmetry trip level: 5% – 25%\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Protection: 500V (fixed)\u003c\/li\u003e\n\u003cli\u003eLow Voltage : 240V (fixed)\u003c\/li\u003e\n\u003cli\u003eError Waiting Time : 0,1 sec. – 20 sec. (adjustable)\u003c\/li\u003e\n\u003cli\u003eReset Time after \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003efault removal\u003c\/span\u003e: 0,1sec. – 20sec. (adjustable)\u003c\/li\u003e\n\u003cli\u003eInsufficient Supply Voltage Protection\u003c\/li\u003e\n\u003cli\u003e4xLED for relay status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eIt is primarily used to safeguard: \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Prevents overheating and burnout from phase imbalances or loss.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eCompressors:\u003c\/strong\u003e Protects against reverse rotation caused by incorrect phase sequence.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Acts as a general-purpose protection relay for three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: 380V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eA\u003cmeta charset=\"utf-8\"\u003esymmetry adjusting: 5\u003cmeta charset=\"utf-8\"\u003e% - 25%\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174059172170,"sku":"FKT-06F","price":24.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Phase_Failure_Asymmetry_and_Under_Over_Voltage_Monitoring_Relay_3_Phase_Fail_Relay_DIN_rail_mount_SPDT_FKT-06F_TENSE.png?v=1768836770"},{"product_id":"phase-neutral-failure-asymmetry-under-over-voltage-monitoring-relay-3-phase-fail-relay-din-spdt-fkm-05f","title":"Phase \/ Neutral Failure, Asymmetry and Under \/ Over Voltage Monitoring Relay, 3 Phase Fail Relay, DIN rail mount, SPDT, FKM-05F, TENSE","description":"\u003ch1 class=\"p1\"\u003ePhase and neutral failure, asymmetry detection and under \/ over voltage protection relay with NO+NC output, DIN rail mount, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe FKM-05F is an asymmetry-adjustable phase failure and sequence monitoring relay with under\/over voltage protection manufactured by Tense Electronics. It is designed to protect three-phase motors and loads from electrical damage caused by AC voltage irregularities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003ePhase Sequence \/ Reverse detection;\u003c\/li\u003e\n\u003cli\u003ePhase loss detection; \u003c\/li\u003e\n\u003cli\u003eNeutral loss detection; \u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eAdjustable phase asymmetry trip level: 5% – 25%\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Protection: 300V (fixed)\u003c\/li\u003e\n\u003cli\u003eLow Voltage : 140V (fixed)\u003c\/li\u003e\n\u003cli\u003eError Waiting Time : 0,1 sec. – 20 sec. (adjustable)\u003c\/li\u003e\n\u003cli\u003eReset Time after \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003efault removal\u003c\/span\u003e: 0,1sec. – 20sec. (adjustable)\u003c\/li\u003e\n\u003cli\u003eInsufficient Supply Voltage Protection\u003c\/li\u003e\n\u003cli\u003e4xLED for relay status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eIt is primarily used to safeguard: \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Prevents overheating and burnout from phase imbalances or loss.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eCompressors:\u003c\/strong\u003e Protects against reverse rotation caused by incorrect phase sequence.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Acts as a general-purpose protection relay for three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: \u003cmeta charset=\"utf-8\"\u003e220V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eA\u003cmeta charset=\"utf-8\"\u003esymmetry adjusting: 5\u003cmeta charset=\"utf-8\"\u003e% - 25%\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN rail.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174060122442,"sku":"FKM-05F","price":24.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Phase_Neutral_Failure_Asymmetry_and_Under_Over_Voltage_Monitoring_Relay_3_Phase_Fail_Relay_DIN_rail_mount_SPDT_FKM-05F_TENSE.png?v=1768835986"},{"product_id":"digital-phase-neutral-failure-asymmetry-under-over-voltage-monitoring-relay-din-rail-mount-spdt-fkv-03hf-tense","title":"Digital Phase \/ Neutral Failure, Asymmetry and Under \/ Over Voltage Monitoring Relay, 3 Phase Fail Relay, DIN rail mount, SPDT, FKV-03HF, TENSE","description":"\u003ch1 class=\"p1\"\u003eDigital phase and neutral failure, asymmetry detection and under \/ over voltage protection relay with NO+NC output, DIN rail mount, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe FKV-03HF is an asymmetry-adjustable phase failure and sequence monitoring relay with under\/over voltage protection manufactured by Tense Electronics. It is designed to protect three-phase motors and loads from electrical damage caused by AC voltage irregularities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003ePhase Sequence \/ Reverse detection;\u003c\/li\u003e\n\u003cli\u003ePhase loss detection; \u003c\/li\u003e\n\u003cli\u003eNeutral loss detection; \u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eAdjustable phase asymmetry trip level: 5% – 50%\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Protection: \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e400V – 480V AC \u003c\/span\u003e\u003cspan\u003e(Adjustable)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow Voltage : \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e260V – 360V AC \u003c\/span\u003e\u003cspan\u003e(Adjustable)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eError Waiting Time : 1 sec. – 30 sec. (adjustable)\u003c\/li\u003e\n\u003cli\u003eReset Time after \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003efault removal\u003c\/span\u003e: 1sec. – 30 sec. (adjustable)\u003c\/li\u003e\n\u003cli\u003e3xLED displays \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eIt is primarily used to safeguard: \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Prevents overheating and burnout from phase imbalances or loss.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eCompressors:\u003c\/strong\u003e Protects against reverse rotation caused by incorrect phase sequence.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Acts as a general-purpose protection relay for three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: \u003cmeta charset=\"utf-8\"\u003e220V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eA\u003cmeta charset=\"utf-8\"\u003esymmetry adjusting: 5\u003cmeta charset=\"utf-8\"\u003e% - 50%\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN rail.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174061203786,"sku":"FKV-03HF","price":29.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Digital_Phase_Neutral_Failure_Asymmetry_and_Under_Over_Voltage_Monitoring_Relay_3_Phase_Fail_Relay_DIN_rail_mount_SPDT_FKV-03HF_TENSE.png?v=1768839499"},{"product_id":"phase-failure-asymmetry-monitoring-relay-3-phase-sequence-relay-din-rail-mount-spdt-fkv-03f-tense","title":"Simple Phase Failure, Asymmetry Monitoring Relay, 3 Phase Sequence Relay, DIN rail mount, SPDT, FKV-03F, TENSE","description":"\u003ch1 class=\"p1\"\u003eSimple phase sequence failure and  asymmetry monitoring relay for 3 phase, DIN rail mount, SPDT, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe FKV-03F is an phase failure and phase sequence monitoring relay with asymmetry monitoring relay manufactured by Tense Electronics. It is designed to protect three-phase motors and loads from electrical damage caused by AC voltage irregularities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003ePhase Sequence \/ Reverse detection;\u003c\/li\u003e\n\u003cli\u003ePhase loss detection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eFixed phase asymmetry trip level: 40%\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eAutomatic reset on fault removal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e3xLED for relay status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eIt is primarily used to safeguard: \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eElectric Motors:\u003c\/strong\u003e Prevents overheating and burnout from phase imbalances or loss.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eCompressors:\u003c\/strong\u003e Protects against reverse rotation caused by incorrect phase sequence.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Acts as a general-purpose protection relay for three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eMonitoring volatage: \u003cmeta charset=\"utf-8\"\u003e3x380V AC 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eP\u003cmeta charset=\"utf-8\"\u003eower supply: \u003cmeta charset=\"utf-8\"\u003e220V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOutput: NO+NC, 5A \/ 250VAC Resistive Load\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;6VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: 35mm DIN rail.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":53174080045386,"sku":"FKV-03F","price":14.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/Simple_Phase_Failure_Asymmetry_Monitoring_Relay_3_Phase_Sequence_Relay_DIN_rail_mount_SPDT_FKV-03F_TENSE.png?v=1768837937"},{"product_id":"dawn-to-dusk-control-switch","title":"Dawn to Dusk Control switch Photocell Sensor 1500W, Outdoor Weatherproof Light Switch IP44, FT-GR, TENSE","description":"\u003ch1 class=\"p1\"\u003eCompact and reliable dusk to dawn photocell sensor 1500W, outdoor weatherproof light switch IP44, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p2\"\u003eCompact p\u003cspan id=\"productTitle\" class=\"a-size-large product-title-word-break\"\u003ehotocell sensor \u003c\/span\u003eFT-GR is of photocell relay manufactured by Tense Electronics, a Turkish company specializing in electrical control and automation components. It is \u003cmeta charset=\"utf-8\"\u003edesigned for systems that require light-intensity dependent control, such as street lighting or illuminated billboards. \u003c\/p\u003e\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e It automatically switches electrical loads (up to 1500W) on or off based on ambient light levels.\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eOperating Threshold:\u003c\/strong\u003e It is typically pre-set to a fixed sensitivity of 10 Lux (fixed delay time for ON and OFF switching- 15 sec.)\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for wall mounting to ensure stable light detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply voltage: \u003cmeta charset=\"utf-8\"\u003e220V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOutput: \u003cmeta charset=\"utf-8\"\u003e7A\/250V AC 1500W(Resistive Load)\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;4VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: Wall mount\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtection degree: IP44.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":60893185114442,"sku":"FT-GR","price":11.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/crp_products-10f43c0f6c03760acff02f915fa1e524-2019-11-28.png?v=1768842575"},{"product_id":"dusk-to-dawn-photocell-sensor-1500w-outdoor-weatherproof-light-switch-ip44","title":"Adjustable Electronic Dusk To Dawn Photocell Sensor, Outdoor Weatherproof Light Switch IP44, FTV-04, TENSE","description":"\u003ch1 class=\"p1\"\u003eCompact and reliable dusk to dawn photocell sensor, outdoor weatherproof light switch IP44, TENSE (Made in Turkey)\u003c\/h1\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cp class=\"p2\"\u003eCompact p\u003cspan class=\"a-size-large product-title-word-break\" id=\"productTitle\"\u003ehotocell sensor \u003c\/span\u003eFTV-04 is of photocell relay manufactured by Tense Electronics, a Turkish company specializing in electrical control and automation components. It is \u003cmeta charset=\"utf-8\"\u003edesigned for systems that require light-intensity dependent control, such as street lighting or illuminated billboards.  \u003c\/p\u003e\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li2\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e It automatically switches electrical loads  on or off based on ambient light levels.\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eOperating Threshold:\u003c\/strong\u003e adjustable sensitivity 1- 10 Lux (fixed delay time for ON and OFF switching 20-60 sec.)\u003c\/li\u003e\n\u003cli class=\"li2\"\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for wall mounting (sensor) to ensure stable light detection and DIN rail (for relay).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply voltage: \u003cmeta charset=\"utf-8\"\u003e220V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eOutput: 5A\/250V AC (Resistive Load)\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt;4VA;\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating temperature: -20C...+55C ;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting: Wall mount+DIN rail\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtection degree: IP44 (sensor).\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":60893266444618,"sku":"FTV-04","price":17.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/FTV-04_FT-G-1.png?v=1768843772"},{"product_id":"3-pole-mini-contactor-230v-ac-coil-3-pole-1no-7-kw-16a-5-5-kw-12a-4-kw-9a-ac-3","title":"16A 3-pole mini  contactor 230V AC Coil, 3-Pole + 1NO, 7 kW-16A \/ 5.5 kW-12A \/ 4 kW-9A, AC-3","description":"\u003ch2\u003e\u003cspan\u003eThis high-performance industrial motor mini-contactor is designed for compact electrical panels and integrated machine control units where space is limited but high power handling is required. It supports panel mounting or installation on a standard 35mm DIN rail.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=xGED5b_6g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],[],null,1]]--\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIExAB\" data-hveid=\"CAIIAAgACBMQAQ\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDevice Type:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Mini AC Contactor (3-Pole)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIExAD\" data-hveid=\"CAIIAAgACBMQAw\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Rating:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e16A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (under AC-3 utilization category at 380\/400V)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIExAF\" data-hveid=\"CAIIAAgACBMQBQ\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePower Rating:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e7 kW\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIExAH\" data-hveid=\"CAIIAAgACBMQBw\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCoil Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 230V AC\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIExAJ\" data-hveid=\"CAIIAAgACBMQCQ\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAuxiliary Contacts:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e  1NO (1 Normally Open built-in auxiliary contact)\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQAA\" data-complete=\"true\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/ul\u003e\n\u003cdiv class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-sfc-inited=\"2\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIFBAA\" data-hveid=\"CAIIAAgACBQQAA\" data-complete=\"true\"\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=xGED5b_7e\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=xGED5b_7e\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eFeatures\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],[],null,1]]--\u003e\n\u003c\/h3\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIFRAB\" data-hveid=\"CAIIAAgACBUQAQ\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSpace Saving:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Designed specifically for tight enclosures and compact control desks where standard contactors cannot fit.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIFRAH\" data-hveid=\"CAIIAAgACBUQBw\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIntegrated Logic:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e The built-in 1NO auxiliary contact allows for electrical latching or status feedback without requiring an add-on auxiliary contact block, reducing costs and wiring footprint.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 id=\"applications-nc6-0901-415v\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIChAB\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eOptimising Motor Control:\u003c\/strong\u003e Advanced industrial starters and bespoke control systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIChAC\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eStreamlining Material Handling:\u003c\/strong\u003e Integrated conveyor systems for efficient product movement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIChAD\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eRegulating Air \u0026amp; Fluid Systems:\u003c\/strong\u003e Smart control setups for heavy-duty pumps and ventilation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIChAE\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePowering OEM \u0026amp; Production Equipment:\u003c\/strong\u003e Automation engineering for machinery manufacturers.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIChAF\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eBuilding Certified Electrical Panels:\u003c\/strong\u003e Custom distribution and control enclosures for any sector.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAAIChAG\" data-complete=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDriving Process Automation:\u003c\/strong\u003e Full-scale machine building and intelligent system integration.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"faq-glow\" id=\"product-faq\"\u003e\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":64068774887754,"sku":"SGC1-M1610","price":7.9,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/16A_3_pole_mini_contactor_230V_AC_Coil_3-Pole_1NO_7_kW-16A_5.5_kW-12A_4_kW-9A_AC-3.png?v=1792769241"},{"product_id":"20a-and-40a-2-pole-2no-din-rail-modular-installation-contactor-silent-contactor","title":"20A and 40A, 2-pole, 2NO, DIN rail modular installation contactor \/ silent contactor, coil 220\/230VAC","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"UTF-8\"\u003eManufactured by electrical automation brands such as Tense Elektronik, this \u003cspan class=\"rQesXe MPyX\"\u003eDIN-rail mount modular contactor\u003c\/span\u003e is engineered for \u003cspan class=\"rQesXe MPyX\"\u003ereliable, silent switching\u003c\/span\u003e of domestic and industrial electrical loads within distribution boards and residential consumer units.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=f31PX_17\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003eKey Specifications\u003c!--TgQPHd|||[[2,[null,null,null,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--\u003e\n\u003c\/h2\u003e\n\u003ch3 class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-wiz-attrbind=\"aria-level=xGED5b_6g\/fLk2Md\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAA\" data-processed=\"true\" data-complete=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAI\" data-sae=\"\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eCurrent Rating:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e20A\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003cstrong\u003e \/ 40A\u003c\/strong\u003e (typically rated under AC-1 \/ AC-7a application categories).\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAI\" data-sae=\"\" data-complete=\"true\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eControl Circuit \/ Coil Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e220V - 230V AC\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e (50\/60Hz)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAc\" data-processed=\"true\" data-sae=\"\" data-complete=\"true\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003ePole Configuration:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e2 Poles\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e with a \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e2NO (Normally Open)\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e contact state configuration.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAw\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eDesign\/Mounting:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eModular DIN Rail\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e type, designed to fit standard electrical control panels alongside consumer components like circuit breakers.\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003cspan\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEBE\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eSpecial Feature:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e Quiet hum-free operation, making it suitable for noise-sensitive residential or office automation spaces.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEBE\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eProtection Degree:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e \u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eIP20\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e rated\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjnnZ7SqtCXAxUWhv0HHSp3FD8Qi4wTegoIAggACAAIFBAA\" data-hveid=\"CAIIAAgACBQQAA\" data-complete=\"true\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"faq-glow\" id=\"product-faq\"\u003e\u003c\/div\u003e","brand":"TENSE","offers":[{"title":"20A","offer_id":64070188007754,"sku":"UEC1-20GC20M7Z","price":9.9,"currency_code":"GBP","in_stock":false},{"title":"40A","offer_id":64070188040522,"sku":"UEC1-20GC40M7Z","price":18.9,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/2-Kutup-Moduler-Kontaktor_1_copy.jpg?v=1792771990"},{"product_id":"3-phase-under-over-voltage-current-monitoring-phase-fail-sequence-control-63a","title":"3 Phase Under \/ Over Voltage Current Protector Smart Control Relay With Phase Fail \/ Sequence Control, DIN Rail Mount, up to 63A","description":"\u003ch2 class=\"p1\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e \u003c\/strong\u003eThe Tense GKE-63T is a 63A-rated, microprocessor-controlled digital 3-phase voltage and current protector.\u003c\/h2\u003e\n\u003ch2 class=\"p1\"\u003e\n\u003cspan class=\"rQesXe MPyX\"\u003eKey Protections:\u003c\/span\u003e High\/low voltage, overload, phase unbalance, phase rotation\/sequence faults, overheating, broken neutral protection, and ultra-fast short-circuit response (0.04s)\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAH\" data-hveid=\"CAIIAAgACBMQBw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAH\" data-hveid=\"CAIIAAgACBMQBw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eOperating Modes:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQCQ\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQCg\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cspan\u003e\u003cstrong\u003eSynchronous Mode: Three-phase single-circuit protection.\u003c\/strong\u003e The monitoring relay protects the three-phase voltage with L1, L2, L3 and N configured as a single circuit.\u003c\/span\u003e\u003cbr\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQCw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"\u003eAsynchronous Mode: Independent Phase-by-Phase Protection\u003c\/strong\u003e\u003cbr data-sfc-root=\"c\" data-sfc-pl=\"|||[]\" data-complete=\"true\"\u003e\u003cspan\u003eIn this mode, the protection relay operates as three independent single-phase protectors. These can be connected to three separate circuits, allowing the monitoring relay to track and register trips, stops, and resets for each individual circuit.\u003c\/span\u003e\u003cbr\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAQ\" data-hveid=\"CAIIAAgACBMQEA\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eAdjustment Ranges:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQEg\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQEw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eCurrent:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 1–63A\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFA\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eLow Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 80–210V\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFQ\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eHigh Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 220–300V\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFg\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eVoltage Asymmetry:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 20–99V, OFF\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eStartup Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 1–300 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eReset Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 1–600 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eUndervoltage trip delay setting:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e0.1s~5.0s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eOvervoltage trip delay setting:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e0s~5s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eOvercurrent trip delay setting:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e0s~600s\u003c\/span\u003e\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAd\" data-hveid=\"CAIIAAgACBMQHQ\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eDesign \u0026amp; Monitoring:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e DIN rail-mounted module with a digital display, internal temperature indicator, and last-fault memory record.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAd\" data-hveid=\"CAIIAAgACBMQHQ\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/gke_63t_en_1.pdf?v=1792777627\" target=\"_blank\" title=\"User Manula for GKE-63T\" rel=\"noopener\"\u003e\u003cspan style=\"color: rgb(24, 24, 247);\"\u003e\u003cstrong\u003eFor more information, please refer to the user manual in the 'Download' section or follow this link.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":64071113212234,"sku":"GKE-63T","price":78.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/GKE-63T_3_Phase_Under_Over_Voltage_Current_Monitoring_Relay_With_Phase_Fail_Sequence_Control_DIN_Rail_Mount_up_to_63A.webp?v=1792775799"},{"product_id":"single-phase-ovp-smart-control-relay-63a","title":"Single Phase Under \/ Over Voltage Current Protector Smart Control Relay DIN Rail Mount, up to 63A","description":"\u003ch2 class=\"p1\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e \u003c\/strong\u003eThe Tense GKE-63E is a 63A-rated, microprocessor-controlled digital one phase voltage and current protector.\u003c\/h2\u003e\n\u003ch2 class=\"p1\"\u003e\n\u003cspan class=\"rQesXe MPyX\"\u003eKey Protections:\u003c\/span\u003e High\/low voltage, overload, overheating, broken neutral protection, and ultra-fast short-circuit response (0.04s)\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/h2\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAH\" data-hveid=\"CAIIAAgACBMQBw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAQ\" data-hveid=\"CAIIAAgACBMQEA\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eAdjustment Ranges:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\n\u003cul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQEg\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQEw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eCurrent:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 1–63A\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFA\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eLow Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 80–210V, OFF\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFQ\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eHigh Voltage:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 220–300V, OFF\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cbr\u003e\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQFw\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eStartup Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 1–300 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eReset Delay:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e 1–600 seconds\u003c!--TgQPHd|||[]--\u003e\u003c\/span\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eUndervoltage trip delay setting:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e 80V:0.1-5.0s ,\u0026lt;80V:0.02s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eOvervoltage trip delay setting:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e\u0026lt;305V:0s-5.0s; 305V: 0.02s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAAgACBMQGA\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eOvercurrent trip delay setting:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e0s~600s\u003c\/span\u003e\u003c\/li\u003e\n\u003c!--TgQPHd|||[]--\u003e\n\u003c\/ul\u003e\n\u003c!--TgQPHd|||[]--\u003e\u003c!--TgQPHd|||[]--\u003e\n\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAd\" data-hveid=\"CAIIAAgACBMQHQ\"\u003e\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003cstrong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003eDesign \u0026amp; Monitoring:\u003c!--TgQPHd|||[]--\u003e\u003c\/strong\u003e DIN rail-mounted module with a digital display, internal temperature indicator, and last-fault memory record.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-bfc=\"\" class=\"\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-ved=\"2ahUKEwicjKzQz9CXAxWrRPEDHWlOJVsQi4wTegoIAggACAAIExAd\" data-hveid=\"CAIIAAgACBMQHQ\"\u003e\n\u003cspan class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/gke_63e_en_1.pdf?v=1792779209\" target=\"_blank\" title=\"User Manual for GKE-63E\" rel=\"noopener\"\u003e\u003cspan style=\"color: rgb(24, 24, 247);\"\u003e\u003cstrong\u003eFor more information, please refer to the user manual in the 'Download' section or follow this link.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":64071468646730,"sku":"GKE-63E","price":25.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/files\/GKE-63E_Single_Phase_Under_Over_Voltage_Current_Protector_Smart_Control_Relay_With_Phase_Fail_Sequence_Control_DIN_Rail_Mount_up_to_63A.webp?v=1792779514"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/0411\/0666\/collections\/Screenshot_2026-01-20_at_11.39.10.png?v=1768909280","url":"https:\/\/pelek.uk\/collections\/control-relays.oembed?page=2","provider":"Principal Elektrik UK Ltd.","version":"1.0","type":"link"}